Low Pressure or Weak Flow

Last Updated:

Use the following checks if your Clarus CF50 system has low pressure or weak water flow.

 

  • Open the air-bleed valve on the filter until water sprays.
  • Check for clogs in the pump basket or skimmer.
  • Ensure the water level is halfway up the skimmer opening.

Yes No

  • Tightly packed or collapsed pleats.
  • Cracked end caps.
  • Oily or slimy buildup that did not rinse off.
  • Visible discoloration or deformity.

Yes No

  • Rinse between all cartridge pleats.
  • Inspect for discoloration, damage, or deformity.
  • Replace the cartridge if it appears worn or misshapen.
  • Reinstall the cartridge and restart the system.

Yes No

  • Is the pump lid O-ring seated properly and free from cracks?
  • Are there any loose unions or cracked suction hoses?
  • Is the pump fully primed, with the basket filled and no bubbles?
  • Have you opened the air-bleed valve on the filter housing until water sprays?

Yes No

  • Are all valves fully open?
  • Are any flow restrictors or small return jets installed?
  • Is the pump appropriately sized? A 0.3-1 HP pump is recommended.
  • Was the filter cartridge cleaned or replaced recently?

Yes No

  • Remove and clean the filter cartridge thoroughly.
  • If it was recently cleaned, inspect it for damage or embedded debris.
  • Check that return valves are fully open and jets are unobstructed.
  • Confirm there are no heaters or other backpressure sources restricting flow.

Yes No

  • Turn off the system and inspect the pump basket.
  • With the power off, carefully check the impeller for debris using a finger or suitable tool.
  • Check for unusual vibration, noise, or overheating from the pump.
  • Make sure the pump lid seals tightly and has no visible cracks.

Yes No